TIL a hot water leak on a tube sheet in East Chicago taught me to check the expansion before blaming the weld
Was doing a hydro on a small boiler in East Chicago last Tuesday and saw water weeping around a tube about 20 minutes into the test. My first gut move was to blame the weld, so I drained it and ground out the joint, which was dumb because the real issue was the tube sitting too proud of the sheet. I re-rolled it with the expander and kept the roller about 1/8 inch back from the sheet face, then ran the test again at 1.5 times the working pressure. Held clean for the full 30 minutes this time. Turned out the tube had been rolled too far in on the first pass, which thinned the wall right at the sheet. How do you all check roll depth before you fire up the pump?